PRODUCTS
Shop
- Uncategorized3 products
- BYD6 products
- Inverter0 products
- MG9 products
- Super B11 products
- Victron425 products
- Accessories59 products
- Battery monitors & batteries98 products
- AGM Battery11 products
- AGM Telecommunications Battery3 products
- Battery Isolators and Combiners19 products
- Battery Management System6 products
- Battery Monitors6 products
- Battery Protect8 products
- democategory0 products
- GEL Deep Cycle7 products
- Inverter/Charger/MPPT6 products
- Lithium Smart Battery19 products
- Lithium SuperPack Batteries5 products
- Peak Power Batteries3 products
- Charge & Convert190 products
- Local & remote monitoring37 products
- Solar chargers & panels45 products
Filter by price
Filter by Brand
BydByd 6
FroniusFronius 1
MGMG 9
SolarSolar 1
SuperbSuperb 10
VictronVictron 414
Top rated products
Showing 409–420 of 442 resultsSorted by popularity
6V/240Ah AGM Deep Cycle Batt.
د.إ1,110.00The AGM range has very low internal resistance making them particularly suitable for high current discharge applications such as for inverters, thrusters and winches. VRLA AGM: design life 7-10 years.
EV Charging station
د.إ1,800.00The EV Charging Station has three phase and single-phase capabilities. It delivers maximum 22kW AC in three phase mode or 7.3kW in single phase mode.
It incorporates 4.3-inch LCD touch screen for monitoring and control.
Fully programmable RGB Light Ring around charging port, to quickly determine the device state.
It can be programmed from the web interface to display different light effects based on the current state (disconnected, charging, charged etc.). The objective is to help the user see the current state from a distance.
Galvanic Isolator VDI-16 A
د.إ420.00The galvanic isolator prevents electrolytic corrosion. It blocks low voltage DC currents that enter your boat via the shore power earth wire. These currents can cause corrosion to the boat’s underwater metals, like the hull, propeller, shaft and so on.
The galvanic isolator consists internally of two diodes which are connected in anti-parallel fashion. When they are connected in this way, the diodes allow current in both directions but only above a certain threshold voltage. The voltage at which diodes conduct is about 1.4 Vdc.
The isolator is installed directly behind your boat’s 230V connection. The forward voltage from the galvanic isolator is higher than the potential difference between metals. As a result, this voltage will not allow conduction and as such, the galvanic isolator will prevent any electrolytic current. However, if there is a (higher) error voltage in the AC circuit, the diodes will allow current through and the residual-current device will break the circuit.
Galvanic Isolator Waterproof (potted)
Maximum current 32 A
Peak current (20 ms) 3200 A
Connection M6
Heat sink
Material Anodized aluminium
Protection category IP 67
Isolation Trans.2000W 115/230V
د.إ1,630.00Safety and prevention of galvanic corrosion
The Isolation Transformer eliminates any electrical continuity between AC shore power and the boat. It is essential for safety and eliminates the need for galvanic isolators and polarity alarms.
Safety is taken for granted in case of a normal on-shore installation. A fuse will blow or a GFCI (Ground Fault Current Interrupter) will trip in case of a short circuit or current leakage to ground. Connecting the ground wire of
the shore-side supply to the metal parts of the boat will result in galvanic corrosion (see below). Bringing only the
live and neutral wire on board results in an unsafe situation because GFCIs will not work nor will a fuse blow in
case of a short circuit to a metal part on the boat.
Galvanic corrosion occurs when two dissimilar metals in electrical contact are simultaneously exposed to an
electrically conducting fluid. Seawater and, to a lesser extent, fresh water are such fluids. In general, the more
active alloy of the couple corrodes preferentially while the less active (more noble) material is cathodically
protected. The rate of galvanic corrosion is a function of several variables including area ratios, conductivity of the
fluid, temperature, nature of the materials, etc.
It is a misunderstanding that galvanic corrosion occurs only in metal and aluminium hulls. In fact it can occur on
any boat as soon as a metallic part (the shaft and propeller) is in contact with water. Galvanic corrosion will
quickly dissolve your sacrificial anodes, and attack the shaft, propeller and other metal parts in contact with water
as soon as the boat is connected to the shore-side supply.
It might therefore be tempting not to connect the ground conductor: this is however extremely dangerous
because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat.
Quattro 12/3000/120-50/30
د.إ6,990.00Similar to the MultiPlus, the Quattro is also a combined inverter and charger. Additionally it can accept two AC inputs and automatically connect to the active source. Its many features include a true sine wave inverter, adaptive charging, hybrid PowerAssist technology plus multiple system integration features such as three or split phase operation and parallel operation.Two AC inputs with integrated transfer switch
The Quattro can be connected to two independent AC sources, for example the public grid and a generator, or two
generators. The Quattro will automatically connect to the active source.
Two AC Outputs
The main output has no-break functionality. The Quattro takes over the supply to the connected loads in the event of a grid
failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and
other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on one of the inputs of the Quattro. Loads that should not discharge the
battery, like a water heater for example, can be connected to this output.
Split phase and three phase capability
Two units can be configured for split phase, and three units can be configured for three phase output. But that’s not all: up to
4 sets of three units can be parallel connected to provide 96W / 120kVA inverter power and more than 1600A charging
capacity
Inverter 12/250 230V VE.Direct UK
د.إ380.00VE.Direct communication port
The VE.Direct port can be connected to:
• A computer (VE.Direct to USB interface cable needed)
• Apple and Android smartphones, tablets, MacBook’s and other devices
(VE.Direct Bluetooth Smart dongle needed)
Fully configurable:
• Low battery voltage alarm trip and reset levels
• Low battery voltage cut-off and restart levels
• Dynamic cut-off: load dependent cut-off level
• Output voltage 210 – 245V
• Frequency 50 Hz or 60 Hz
• ECO mode on/off and ECO mode sense level
Monitoring:
• In- and output voltage, % load and alarms
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverters are short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset value (min load: 15W). Once in
standby the inverter will switch on for a short period (adjustable, default: every 2,5 seconds). If the load exceeds a preset level,
the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two-pole connector, or between battery plus and the left-hand contact of the
two-pole connector.
LED diagnosis
Please see manual for a description.
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters, we recommend our Filax Automatic Transfer Switch. The Filax features a very short switchover time
(less than 20 milliseconds) so that computers and other electronic equipment will continue to operate without disruption.
Blue Smart IP65 Charger 12/7(1) 230V UK Retail
د.إ400.00Features:
With up to 95% efficiency, the IP65 chargers generate up to four times less heat when compared to the industry standard. And once the battery is fully charged, power consumption reduces to 0,5 Watt, some five to ten times better than the industry standard.
Storage mode:
less corrosion of the positive plates Even the lower float charge voltage that follows the absorption period will cause grid corrosion. It is therefore essential to reduce the charge voltage even further when the battery remains connected to the charger during more than 48 hours.
Temperature compensated charging:
The optimal charge voltage of a lead-acid battery varies inversely with temperature. The Blue Power IP65 Charger measures ambient temperature during the test phase and compensates for temperature during the charge process. The temperature is measured again when the charger is in low current mode during float or storage. Special settings for a cold or hot environment are therefore not needed.
Li-ion battery mode:
The Blue Power IP65 Charger uses a specific charging algorithm for Li-ion (LiFePO₄) batteries, with automatic Li-ion under voltage protection reset.
Recovery function for fully discharged batteries:
Most reverse polarity protected chargers will not recognize, and therefore not recharge a battery which has been discharged to zero or nearly zero Volts. The Blue Power IP65 Charger however will attempt to recharge a fully discharged battery with low current and resume normal charging once sufficient voltage has developed across the battery terminals.
Functions:
Water, dust and chemical resistant
Seven step smart charge algorithm
Recovery of fully discharged ‘dead’ batteries
Automatic power supply function
Automatic compensation for high or low temperature
Several other battery life enhancing features
Low power mode to charge smaller batteries
Li-ion battery mode”
Blue Smart IP65s Charger 12/5(1) 230V UK Retail
د.إ310.00Features:
With up to 95% efficiency, the IP65 chargers generate up to four times less heat when compared to the industry standard. And once the battery is fully charged, power consumption reduces to 0,5 Watt, some five to ten times better than the industry standard.
Storage mode:
less corrosion of the positive plates Even the lower float charge voltage that follows the absorption period will cause grid corrosion. It is therefore essential to reduce the charge voltage even further when the battery remains connected to the charger during more than 48 hours.
Temperature compensated charging:
The optimal charge voltage of a lead-acid battery varies inversely with temperature. The Blue Power IP65 Charger measures ambient temperature during the test phase and compensates for temperature during the charge process. The temperature is measured again when the charger is in low current mode during float or storage. Special settings for a cold or hot environment are therefore not needed.
Li-ion battery mode:
The Blue Power IP65 Charger uses a specific charging algorithm for Li-ion (LiFePO₄) batteries, with automatic Li-ion under voltage protection reset.
Recovery function for fully discharged batteries:
Most reverse polarity protected chargers will not recognize, and therefore not recharge a battery which has been discharged to zero or nearly zero Volts. The Blue Power IP65 Charger however will attempt to recharge a fully discharged battery with low current and resume normal charging once sufficient voltage has developed across the battery terminals.
Functions:
Water, dust and chemical resistant
Seven step smart charge algorithm
Recovery of fully discharged ‘dead’ batteries
Automatic power supply function
Automatic compensation for high or low temperature
Several other battery life enhancing features
Low power mode to charge smaller batteries
Li-ion battery mode
Autotransformer 120/240VAC-100A
د.إ1,960.00For step up, step down and split phase balancing. An Autotransformer can be used for step up, step down and split phase output balancing purposes. While the step up and step down functions are fairly straightforward, split phase output balancing may require some more attention.
Autotransformer 120/240VAC-32A
د.إ1,840.00For step up, step down and split phase balancing. An Autotransformer can be used for step up, step down and split phase output balancing purposes. While the step up and step down functions are fairly straightforward, split phase output balancing may require some more attention.
SUPER B NOMIA 12V340AH
Super B The Nomia 12V340Ah is a Lithium Iron Phosphate battery (LiFePO4) with a rated capacity of 340Ah. The unique combination of state-of-the art technology and smart software makes this lithium battery a robust, safe and easy to use energy storage solution. Compared to conventional lead-acid batteries, the Super B Nomia 12V340Ah lithium battery offers an enormous weight and space saving. It is very efficient, has extremely high performances and is maintenance free.